audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Lines, Disconnecting and Connecting From Compressor|Page 1804 > < Hose/Line HVAC|Description and Operation|Page 1801
Page 1
background image

Hose/Line HVAC: Service and Repair
Refrigerant Lines, Disconnecting and Connecting From Compressor

Refrigerant Circuit

Refrigerant Lines, Disconnecting and Connecting from Compressor

‹› Compressor is always driven when engine is running; there is no magnetic clutch. Engine is therefore not to be started unless refrigerant circuit has

been properly assembled. If for example the refrigerant lines are not connected to the compressor and the engine is started then the compressor
may be destroyed by the build-up of internal heat.

‹› The following illustrations show a compressor installed on left of engine, refrigerant lines with compressor installed at other locations are to be

removed the same way.

‹› Seal open pipes and connections at compressor with suitable caps to prevent ingress of dirt and moisture.

Removing

-

Remove upper engine cover, vehicles with 8 cylinder. diesel engine only.

-

Drain the refrigerant circuit.

-

On vehicles with 8 cylinder. FSI engine, perform the preparatory work described. Refer to => [ Compressor, 8 Cylinder FSI ] See: Heating and Air
Conditioning/Compressor HVAC/Service and Repair

-

On vehicles with 10 cylinder engine, perform the preparatory work described. Refer to=> [ Compressor, S8 10 Cylinder ] See: Heating and Air
Conditioning/Compressor HVAC/Service and Repair

-

On vehicles with 12 cylinder engine, perform the preparatory work described. Refer to=> [ Compressor from Bracket, 12 Cylinder ] See: Heating
and Air Conditioning/Compressor HVAC/Service and Repair

-

Remove compressor from bracket, not for vehicles with 8 cylinder diesel engine. Refer to => [ Compressor, Removing from Bracket, 6 Cylinder, 8
Cylinder MPI and 8

Cylinder Diesel ] See: Heating and Air Conditioning/Compressor HVAC/Service and Repair

-

Remove bolts - A -.

-

Disconnect refrigerant lines - B - and -  C -.

Installing

Installation is carried out in the reverse order, when doing this note the following:

-

Replace O-rings seals - D - and - E -, version. 

-

Tighten bolts - B - to 25 Nm.

Refrigerant Lines, Disconnecting and Connecting From Compressor|Page 1804 > < Hose/Line HVAC|Description and Operation|Page 1801