Secondary Air Injection Combination Valves, Checking for Function and Leaks
Special tools, testers and auxiliary items required
‹› Hand Vacuum Pump (VAS 6213)
Procedure
-
Pull rear engine cover off - arrows -.
-
Remove the vacuum hose - 3 - from the secondary air injection combination valve - 2 -.
-
Remove the secondary air hose - 1 - by pressing the release buttons.
-
Connect the Hand Vacuum Pump (VAS 6213) to the vacuum connection - 1 - on the secondary air combination valve that will be tested.