audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

EVAP Canister Purge Valve 1, Checking|Page 4533 > < EVAP Canister Purge Valve 1, Checking|Page 4531
Page 3
background image

-

Crank the engine.

Specified value: battery voltage.

If the specified value was not obtained:

-

Using a Multimeter, check the electrical harness connector terminal 1 to Ground (GND) for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the wiring connection from the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical harness connector terminal
1 to theEngine Component Power Supply Relay (J757) terminal 2/87 for an open circuit or short to ground (GND).

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Computers
and Control Systems/Engine Control Module/Service and Repair.

-

Using a Multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical connector terminal 2 to theEngine
Control Module (ECM) (J623) electrical connector T94 terminal 9 for an open circuit.

EVAP Canister Purge Valve 1, Checking|Page 4533 > < EVAP Canister Purge Valve 1, Checking|Page 4531