Crank the engine.
Specified value: battery voltage.
If the specified value was not obtained:
-
Using a Multimeter, check the electrical harness connector terminal 1 to Ground (GND) for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
If the specified value was not obtained:
-
Check the wiring connection from the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical harness connector terminal
1 to theEngine Component Power Supply Relay (J757) terminal 2/87 for an open circuit or short to ground (GND).
-
Check the electrical harness connector for damage, corrosion, lose or broken terminals.
-
If necessary, repair the wiring connection.
If the specified value was obtained:
Checking wiring
If the manufacturers test box is being used. Perform the following step.
-
Install the test box.
If the manufacturers test box is not being used. Perform the following step.
-
Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Computers
and Control Systems/Engine Control Module/Service and Repair.
-
Using a Multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical connector terminal 2 to theEngine
Control Module (ECM) (J623) electrical connector T94 terminal 9 for an open circuit.