audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3594 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3592
Page 2
background image

-

Disconnect the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 1 -.

Checking internal resistance

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) terminals 3 to 4 for resistance. 

Specified value: 2.5 to 10.0 ohms (at approx. 20 °C)

If the specification was not obtained:

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3594 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 3592