A8 Quattro Sedan V8-4.2L (BVJ) (2008)
High Pressure Sensor / Switch: Description and Operation
A/C Refrigerant High Pressure Switch F23
Refrigerant Circuit Switches And Sensors And Related Connections
NOTE: Refer to vehicle-specific refrigerant circuit for switching pressures, switch removal/installation and switch layout/design Heating, air
conditioning or Air conditioning.
A/C Refrigerant High Pressure Switch F23
Function: Switches coolant fan up to next speed setting in the event of pressure increase (approx. 16 bar) in refrigerant circuit.