audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 1215 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 1213
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensors and Oxygen Sensor Regulation Before Catalytic Converter, Checking

Oxygen Sensor and Oxygen Sensor Regulation before Catalytic Converter, Checking

Heated Oxygen Sensor 1

‹› Use only gold-plated terminals when servicing terminals in the electrical harness connectors of the Heated Oxygen Sensor (HO2S) (G39).

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹›  The Motronic Engine Control Module (ECM) (J623) fuses OK.

‹› The Oxygen Sensor (O2S) Heater (Z19) before catalytic converter OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Exhaust system between catalytic converter and cylinder head properly sealed.

‹› Coolant Temperature at least 80 °C.

Function test

-

Perform the function test located in diagnostic mode 06. Refer to => [ OBDMID 01 ($01): Oxygen Sensor

Monitor Bank 1 - Sensor 1 ] See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/Diagnostic Modes 01 - 09/Diagnostic Mode 06 - Read Test Results For Specific Diagnostic Functions.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

Procedure

-

Remove the rear engine cover - arrows -.

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 1215 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 1213