audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Ignition Key In Signal, Antitheft|Service and Repair|Page 5754 > < Ignition Key In Signal, Antitheft|Service and Repair
Page 2
background image

The upper line indicates that 2 ignition keys are adapted to the system.

NOTE:  The number of keys to be adapted can also be entered via button 1 (decrease number) and button 3 (increase number).

-

Press -> button.

Indicated on display

Channel 21 Adaptation 2 

->

Input adaptation value XXXXX

-

Press the -0- button four times and then the total number of keys to be adapted, including the key that is in the ignition (e.g. 00004), max. 8 keys
possible.

-

Press -Q- button to confirm input.

Indicated on display for 4 keys to be adapted:

Channel 21 Adaptation 4 

Q

<-1 3->

-

Press -Q- button to confirm input.

Indicated on display

Channel 21 Adaptation 4 

Q

Store changed value?

NOTE:  No single key must require more than 30 seconds during adaptation, otherwise the warning lamp will blink with a frequency of 2 Hz and
adaptation must be performed again in its entirety (login procedure and adaptation).

-

Press -Q- button to confirm input.

Indicated on display

Channel 21 Adaptation 4 

->

Changed value is stored

Warning lamp in instrument cluster goes out, key in ignition is now adapted.

-

Press -> button.

Indicated on display

Rapid data transfer 

HELP

Select function XX

-

Press buttons -0- and -6-. This selects "End Output", function 06.

Indicated on display

Rapid data transfer 

Q

06 End Output

-

Press -Q- button to confirm input.

Indicated on display

Rapid data transfer 

HELP

Insert address word XX

-

Insert next key in ignition lock and switch on ignition. Warning lamp lights up when ignition is switched on and goes out after approx. one second.
This key is also adapted now.

-

Repeat procedure until all keys have been adapted. After the last key, the warning light will go out approx. 2 seconds after successful adaptation
and a short confirmation signal will be given (0.5 seconds light off, 0.5 seconds light on, light off).

-

During adaptation of vehicle keys, the fixed code of each key (transponder) is adapted to the immobilizer. Furthermore, the computational rule for

Ignition Key In Signal, Antitheft|Service and Repair|Page 5754 > < Ignition Key In Signal, Antitheft|Service and Repair