Battery: Testing and Inspection
Specific Gravity In All Cells, Checking

Specific Gravity In All Cells, Checking

WARNING!

-

Always observe accident prevention precautions when working with battery acid. Appropriate protective clothing must be worn at all
times.

-

Always observe all regulations regarding disposal of batteries and battery acid when disposing of battery.

-

Be sure to observe the following notes, or else a proper test cannot be guaranteed.

The specific gravity test, in combination with the battery load test, provides precise information about the condition of the battery.

Special tools and equipment

-

Commercially available hydrometer

-

Cleaning rags

NOTE:

-

A battery temperature of at least 10 °C is required to check the specific gravity

-

The specific gravity can be checked directly after the battery is charged

-

Unscrew all battery caps (battery cell plugs).