audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Supply Sensor 3 -G237- (Tubular Sender - Right Side), Testing|Page 19241 > < Fuel Supply Sensor 3 -G237- (Tubular Sender - Right Side), Testing
Page 2
background image

-

Connect multimeter between contacts 2 and 3 on connector -A- to measure resistance range.

-

If the resistance is 0 Ohms. there is a short circuit. If the resistance is x Ohms. there is an open circuit in the wiring.

Note:  To test the maximum and minimum resistance values for "tank full" and "tank empty" remove the Fuel Supply Sensor 3 -G237- and move the
sender float all the way to its top or bottom position.