management and that he/she can recognize the disconnection with the help of the trunk light.

3.

Read DTC memory of the Battery Energy Manager (BEM) and check any entries for references on "static current stage 2 or higher (sporadic)".
(illustration is an example only).

If there are no entries:

^

The cut-off may have occurred prior to 50 engine starts (after 50 engine starts, sporadic DTCs are erased automatically).

If the BEM is switched OFF, the trunk lid open/close function is also OFF and the concern can be easily checked.

-

Explain the BEM function to the Customer (as described in the Owner's Manual under Vehicle operation - "Intelligent technology - "Energy
management") and that he can see by the trunk light whether the BEM is working.

Service solution to concern 4:

To avoid further damage:

-

Explain to the customer (as described in the Owner's Manual under Controls and equipment - "Opening and closing - Automatic rear lid /
Trunk lid operation" the following:

-

That the automatic opening and closing must only be interrupted by pressing the buttons on the vehicle or on the remote key again.

-

That if the automatic open/close feature has been interrupted, the lid must be opened or closed manually (like a mechanical trunk lid).

Tip:

^

Always observe the battery voltage. When the engine is on (high battery voltage) the trunk lid drive normally works correctly.

^

On 2004 through 2006 MY vehicles, the joints of the trunk lid hinges must be lubricated with universal oil Part No: G 000 115 A2 at every
service (Maintenance tables will be changed to reflect this change).

Warranty:

If trunk lid replacement is required:

-

It is mandatory to contact the Audi Helpline via Hotline channel (please attach pictures).