audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heating and A/C Unit Heat Exchangers, Removing and Installing|Page 6822 > < Heating and A/C Unit Heat Exchangers, Removing and Installing|Page 6820
Page 3
background image

-

Check both coolant pipes -B- and connections at heat exchanger -C- for damage and dirt.

NOTE:  Sealing rings must always be replaced.

-

Moisten sealing ring -A- slightly with coolant and attach it to coolant pipe -B-.

-

Attach retainer -A- (with studs) to connection at heat exchanger -B- as shown in illustration.

-

Attach retainer -C- (with holes) to coolant pipe -D- as shown in illustration.

-

Insert coolant pipe -D- (with sealing ring) into connection of heat exchanger -B-.

-

Secure coolant pipe in heat exchanger with retainers -C- and -D-.

-

Tighten both hex nuts -A- and -B- alternately and evenly (tightening torque 3 Nm).

NOTE:

-

Retainers -C- and -D- must be fitted as shown in illustration (pay attention to external shape).

-

When tightening hex nuts, take care not to tilt retainers.

-

After securing coolant pipes, check position of retainers. They must not make contact with other components.

-

Install second coolant pipe in the same way.

-

Before installing glove compartment, check cooling system for leaks.

-

Before installing glove compartment and plenum chamber cover, check position of grommet in coolant pipe penetration to plenum chamber.

-

Before attaching 2-pin connector to Coolant Pump -V50- of pump/valve unit, bleed coolant circuit

NOTE:
-

Coolant Pump -V50- of pump/valve unit should not be started up until coolant circuit has been bled.

Heating and A/C Unit Heat Exchangers, Removing and Installing|Page 6822 > < Heating and A/C Unit Heat Exchangers, Removing and Installing|Page 6820