audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Lines, Disconnecting and Connecting From Compressor|Page 15760 > < Refrigerant Lines, Disconnecting and Connecting From Compressor
Page 2
background image

‹› Do not use the O-rings from the shipping caps that are installed on the connections of replacement compressor when installing lines.

‹› Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Description and

Operation/Refrigerant Circuit O-Ring Seals.

‹› Following attachment of refrigerant pipes to compressor and installation of compressor check routing of pipes. They must be inserted in holders

provided and not make contact with other components.

-

Evacuate refrigerant circuit and recharge again.

-

Operate the A/C system after filling the refrigerant circuit. Refer to => [ Operating A/C System after Filling Refrigerant Circuit ] See: Description
and Operation/Operating A/C System after Filling Refrigerant Circuit

‹› Note the information regarding operating the A/C system after filling.

Refrigerant Lines, Disconnecting and Connecting From Compressor|Page 15760 > < Refrigerant Lines, Disconnecting and Connecting From Compressor