audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Intake Air Switch-Over Valve -N335- Checking|Page 9163 > < Intake Air Switch-Over Valve -N335- Checking|Page 9161
Page 1
background image

Variable Induction Control Valve: Testing and Inspection
Intake Manifold Change-Over Valve - N156-, Checking

Intake Manifold Change-Over Valve -N156-, Checking

Checking Intake manifold change-over valve electrically

-

Disconnect connector from Intake Manifold Change-Over Valve -N156-.

-

Perform a resistance measurement between the valve terminals using V.A.G 1526.
Specified value: 25 to 35 Ohms

If specified value is not obtained.

-

Replace Intake Manifold Change-Over Valve -N156-.

If specified value is obtained.

-

Check voltage supply.

Checking voltage supply of Intake Manifold Change-Over Valve

-

Connect V.A.G 1527 voltage test lamp between connector terminal 2 and engine Ground (GND) using adapter cables from V.A.G 1594 connector
test kit.

-

Switch ignition on.

LED must light up.

-

LED does not light up.

-

Check fuse for intake manifold change-over valve (relay- and fuse holder in instrument panel, right side).

If fuse is OK.

-

Check wire connection from terminal 2 of connector for intake manifold change-over valve via fuse to Motronic Engine Control Module (ECM)
Power Supply Relay -J271- (relay carrier in E-box in plenum chamber) for open circuit/short circuit.

If voltage supply is OK, check wire connection.

Checking wire connection from Intake Manifold Change-Over Valve

-

Connect V.A.G 1598/31 test box to wiring harness of Engine Control Module (ECM).

-

Check the following wire connection for open circuit/short circuit:

Connector at wiring

V.A.G 1598/31 test box or

Intake Air Switch-Over Valve -N335- Checking|Page 9163 > < Intake Air Switch-Over Valve -N335- Checking|Page 9161