Control Module: Customer Interest
A/C, Cooling System - Poor Heater Output

80 Poor or no heating in any or all heating zones

19 10 03 

2016703/3 

June 2, 2010

Supersedes Technical Service Bulletin Group 19 number 08-20 dated December 9, 2008 for reasons listed below.

Affected Vehicles

Condition

Poor or no heating in any or all heating zones of the vehicle.

W12 only: ECM software updated with modified map-controlled coolant thermostat specifications. The TCM software must also be updated to be
compatible with the new ECM software level.

Check vehicle campaign history to see whether RVU IJ or RVU IK was performed. If RVU IJ or RVU IK was performed, no further repairs are allowed
by this TSB.

Technical Background

Possible engine coolant scaling in HVAC system.

Production Solution

Improved internal heater core coating.

Service

Silicate Cartridge Installation

Warning:

Hot steam and/or hot coolant can escape when the expansion tank is opened. Wrap a cloth around the filler cap and open carefully.