Air Door Actuator / Motor: Service and Repair
Air Flow Flap Motor -V71-

Air Flow Flap Motor -V71-, Removing and Installing

NOTE:

-

Mark connecting element motor/flap when removing (danger of swapping with connecting elements of the other actuator motors).

-

For the malfunction "adaptation limit exceeded", check connecting element at motor there must be no play between the shaft of the actuator motor
and the connecting element.

-

If the actuator motor makes clicking or rattling noises in regular intervals (approx. every 7 minutes).

-

Remove plenum cover.

-

Remove cover with air flow flap.

-

Remove 2 screws -A- and remove flap motor.

-

Before installing the motor, check mounting of the air flow flap (knob -C- must be positioned between the stops -D-).

-

If shaft of motor is positioned in such a way that it is not possible to install motor, see instructions regarding installation.

-

Tighten securing screws -A- only by hand, tightening torque 8 Ncm (0.7 in. lb).

-

After installing cover, check that grommet -B- is correctly located.

-

After installing, always check DTC memory