audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Battery, Charging|Page 3961 > < Battery, Charging|Page 3959
Page 3
background image

The following values must be attained:

State of charge in  

Specific gravity (kg/dm3)

normal climatic zones 

discharged 

1.12

half-charged 

1.20

good charge 

1.28

CAUTION!

-

To guarantee proper sealing of various battery cover systems, it is necessary to use the original sealing plugs belonging to that battery. If
lost or damaged, use only original sealing plugs of the same construction.

-

Plugs must be equipped with an O-ring seal.