Installing

NOTE:  Install linkage in park position as shown in illustration.

-

Insert linkage and wiper motor in plenum chamber and connect electrical connector.

-

Tighten mounting bolts -2- to 6 Nm.

-

Tighten mounting nuts -1- to 16 Nm and mounting nuts -3- to 4 Nm.