Climate Control Exhaust Gas Sensor: Description and Operation

Air Quality Sensor Function

‹› Depending on setting in MMI (Multi Media Interface), the sunroof closes as soon as front A/C control head Climatronic Control Module (J255)

switches over to air recirculation mode automatic air recirculation via air quality sensor or manual air recirculation by operating the air
recirculation button. This function is equipment-dependent, its introduction has not yet been finalized. => Owner's Manual

‹› Air Quality Sensor (G238) detects pollutants in the ambient air mostly gasoline and or diesel exhaust and orders front A/C control head

Climatronic Control Module (J255) to switch the air conditioning system to recirculating air mode.

‹› Front A/C control head Climatronic Control Module (J255) detects the type and intensity of air pollution at signal from sensor. Depending on the

outside temperature and the intensity of air pollution, front A/C control head Climatronic Control Module (J255) then decides:

-

At an outside temperature greater than approximately + 2 °C (36 F) the recirculating air mode is switched on when there is only a slight increase in
pollutants in the ambient air

-

 At an outside temperature between approximately + 2 °C and approximately - 8 °C, the change over to recirculating air mode only occurs at a
sharp increase of pollutant concentration, during which the compressor is switched on simultaneously

-

 At an outside temperature less than approximately - 8 °C, the change over still occurs only at a sharp increase of pollutant concentration and then
only for approximately 15 seconds compressor is not switched on. 

-

If the concentration drops, the climate control system switches over to the fresh air mode.

‹› The function "Automatic air recirculation" can be switched off at any time. If the function is active and a request for "Automatic air recirculation"

is present the compressor is also switched on when outside temperatures are smaller than + 2 °C. Compressor operation is not possible with
temperatures lower than approximately - 8 °C

‹› At setting "automatic air recirculation" on front A/C control head Climatronic Control Module (J255) or in MMI (Multi Media Interface),

compressor can be switched on also by switching on recirculating air manually (via "recirculating air button") up to a temperature of
approximately - 8 °C.

‹› To ensure that the A/C does not operate constantly in the recirculating air mode in areas with a consistently higher pollution, the sensor is

self-adapting, it adjusts its sensitivity to the environmental conditions.

‹› If outside air pollution load remains high for longer period of time, the sensor starts to adapt itself to the changing environmental condition

through an adaptation program learning program, the air recirculation request in evenly polluted ambient air is therefore generally shorter than 12
minutes. If a succession of peaks in the polluted air is detected, the air conditioning system can operate over a longer period of time in recirculated
air mode. 

‹› A certain amount of time is required for repositioning of the air conditioning system doors. In the event that a sudden increase in pollutants is

encountered like when driving through a diesel exhaust cloud gaseous pollutants can be taken in with the fresh air into the passenger compartment
until the doors can be closed. For this reason, a dust and pollen filter is installed with a charcoal layer. A filter that is saturated with pollutants is no
longer effective and needs to be replaced. Refer to => [ Dust and Pollen Filter ] See: Description and Operation/Air Distributor Housing. 

‹› In order to avoid frequent shifting of the recirculating air/fresh air doors, a slight increase of pollutants in the ambient air will not allow for

immediate shifting the sensor does not send a request to front A/C control head Climatronic Control Module (J255). The filtering of the charcoal
insert in the dust and pollen filter will be sufficient. Refer to => [ Dust and Pollen Filter ] See: Cabin Air Filter/Description and Operation.

‹› In order to avoid frequent shifting of the recirculating air/fresh air door, the requirement from the sensor for "Automatic air recirculation " mode

remains for at least 25 seconds minimum duration period, even if the pollutant concentration is so far reduced that recirculating air mode is no
longer necessary.

‹› If the compressor is shut off in "Econ" or A/C mode, the Climatronic Control Module (J255) front A/C control head limits the "automatic

recirculation mode" to approximately 15 seconds the prevent the windows from fogging.

‹› In order to defog windows as quickly as possible, front A/C control head Climatronic Control Module (J255) does not permit recirculating air

operation during "Defrost" operating mode.

‹› After the ignition is switched on, Air Quality Sensor (G238) requires approximately 30 seconds to be operational warm-up time. During this time

there is no request from the sensor to A/C control head Climatronic Control Module (J255) for " Automatic recirculating air" mode.

‹› The Sensor For Air Quality (G238) contains a highly sensitive electronic component which can be damaged if it comes in direct contact with

solvents, fuels or chemicals. For this reason, do not install sensors that may have come into contact with these substances.

Climate Control Exhaust Gas Sensor|Testing and Inspection > < Ambient Temperature Sensor / Switch HVAC|Service and Repair|Page 15224