Disconnect the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector -  4 -.

Checking primary voltage

-

Switch the ignition on.

-

Using a multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector
terminals 3 to 4 for voltage.

Specified value: 0.400 to 0.500 Volts