Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

Check the wiring connection from the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 to theEngine Component
Power Supply Relay (J757) terminal 2/87 for an open circuit or short to ground (GND).

-

If necessary, repair the faulty wiring connection.

It the specification was obtained.

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Computers
and Control Systems/Engine Control Module/Service and Repair.

-

Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminals to theMotronic Engine Control
Module (ECM) (J623) electrical harness connectors T94 terminals for an open circuit. 