audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

How to Find Wiring Diagrams|Page 8324 > < How to Find Wiring Diagrams|Page 8322
Page 3
background image

Indicated on display
-

Brake pedal must not be used during test activation.
Pump evacuates brake booster. On Board Diagnostic (OBD) for brake booster system is carried out simultaneously in the control module. Test is
passed if pressure in brake booster reaches the cut-off pressure in allowed time (20 sec.).

Indicated on display
-

Disconnect diagnostic cable from Data Link Connector (DLC). 
Or:

Indicated on display
If system is identified as not O.K., DTC memory must be checked and the malfunction must be repaired (ignition off!).
-

Test must be repeated afterward.

Output Diagnostic Test Mode (function 03) 

-

Connect scan tool with diagnostic cable and select function "engine electronics".

-

- Press (arrow) button.

Indicated on display
-

Press buttons O and 3 for output diagnostic test mode and press Q button to confirm input.

-

Press (arrow) button until the following text appears:

Indicated on display
-

Press Q button to confirm input.
The electric vacuum pump must run for about 10 sec.!  

-

Disconnect diagnostic cable from Data Link Connector (DLC) 

How to Find Wiring Diagrams|Page 8324 > < How to Find Wiring Diagrams|Page 8322