audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oil Pressure Gauge|Service and Repair|Page 3781 > < Oil Pressure Gauge|Service and Repair|Page 3779
Page 5
background image

1

-

Enter adaptation value input value 0 to 65535

-

Enter 5-digit adaptation value in button field -2-. If necessary, insert zeros in front.

Example:
Desired input value: 1
Keypad input: 00001

Display on VAS5051:

1

-

Channel X save

2

-

Text display of selected channel or No indication

4

-

original value X new value X

-

Confirm new adaptation value by pressing the "take over" button -3-.

Display on VAS5051:

1

-

Channel X Value X stored

-

End function "10 - Adaptation" by pressing <- button.

Adaptation channel 35 -Adaptation of the engine speed threshold

This function is used to adapt the offset value For the engine speed threshold to the dynamic oil pressure warning. 

Display on VAS5051:

Oil Pressure Gauge|Service and Repair|Page 3781 > < Oil Pressure Gauge|Service and Repair|Page 3779