Air Door Actuator / Motor: Service and Repair
Recirculation Flap Motor -V113-

Recirculation Flap Motor -V113-, Removing And Installing

NOTE:  This positioning motor actuates the fresh air/recirculating air flap.

-

Remove glove box

-

Recirculation Flap Motor -V113-, removing.

-

Disconnect harness connector -A-.

-

Remove bolt -B-.

NOTE:  When removing screw -B-, if necessary reach the bolt from underneath in the recirculating intake area.

-

Remove bolts -C-.

-

Remove positioning motor.

Notes for installation:

-

After installing, always carry out On Board Diagnostic (OBD) of air conditioning system.

-

Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm on the positioning motor).

-

When installing positioning motor; make sure guiding pin -D- engages properly in lever -E-.