Climate Control Exhaust Gas Sensor: Testing and Inspection

Sensor For Air Quality -G238-, Checking

Special tools and equipment

-

VAS 5051 Vehicle Diagnostic, Testing and Information System with diagnostic cable VAS 5051/1

-

Test gas D 007 855 A2

Test requirements:

-

Vehicle is in area where there is clean recirculating air (not near running engines, openings from exhaust systems, etc.)

-

Engine compartment and plenum chamber are clean (not contaminated with oil and/or fuel).

-

The engine compartment and plenum chamber were not sprayed with cleaning or preservative solutions.

Checking

-

With ignition switched off, connect VAS 5051 Vehicle Diagnostic, Testing and Information System with diagnostic cable VAS 5051/1 to 16-pin
diagnostic connector on vehicle. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks" under "Heating and Air Conditioning", 
See: Testing and Inspection 

-

Start engine.

-

Check DTC Memory

-

Select "Auto" operating mode on A/C Control Head -E87-.

-

Press button -A- for "Automatic air recirculation" (LED in -A- button comes on).

-

Wait 30 seconds (warm up time of sensor for air quality -G238-).

Indicated on display of VAS 5051:

-

Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.

-

Remove plenum cover.

Indicated on display of VAS 5051: