Allroad Quattro V6-2.7L Turbo (APB) (2002)
Housing Assembly HVAC: Service and Repair
Air Distributor Housing, Disassembling/Assembling
Air Distribution Housing, Disassembling And Assembling
-
Disassembling and assembling air conditioner unit.
NOTE:
Starting September 1998, there was a running change in production from the version "1" air conditioner to the version "2" air conditioner.
From model year 2002 air conditioner version "3" is installed
From model year 2002 for vehicles with compressor using A/C Compressor Regulator Valve -N280-, an additional Evaporator Vent
Temperature Sensor is installed.(On vehicles without -G263- the opening is closed with a plug).
1. Bolt
2. Clip
3. Foam sealing pad
For condenser drainage duct
4. Bottom section of air distributor housing
With condensation drainage duct
Lower part of version "2" was adapted to modified evaporator
5. Drip pan
For condensation from evaporator