audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

How to Find Wiring Diagrams|Page 4740 > < How to Find Wiring Diagrams|Page 4738
Page 2
background image

If specified value is not obtained, check wire connections.

-

Connect multimeter to terminal 3 and terminal 1 of connector for voltage measurement.

-

Switch ignition on.
Specification: approx. 5 volts.

If specified value is not obtained, check wire connections.

Wire connections for Mass Air Flow (MAF) sensor, checking (Hitachi MAF sensor)

NOTE:  Signal wire is also checked during wire test

-

Connect VAG1598/31 test box at wiring harness to ECM, do not connect ECM. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial
Checks/Connecting VAG1598/31 Test Box" See: Computers and Control Systems/Testing and Inspection  

The following wire connections must be checked for short circuit to B+, Ground (GND) and for open circuit

Connector for Mass

VAG1598/31 test box

Air Flow (MAF) 

terminal

sensor -G70-

1

53

3

27

4

29

Voltage supply for Mass Air Flow (MAF) sensor, checking (Bosch MAF sensor)

-

Disconnect connector from Mass Air Flow (MAF) sensor.

-

Connect multimeter to terminal 2 of connector and engine Ground (GND) for voltage measurement.

-

Operate starter briefly.
Specification: approx. battery voltage

NOTE:  Voltage is supplied to Mass Air Flow (MAF) sensor from Fuel Pump (FP) relay.

How to Find Wiring Diagrams|Page 4740 > < How to Find Wiring Diagrams|Page 4738