1

-

Enter channel number Max. input value = 99

-

Select function "03" in button field -2- For "Adaptation channel 03" and press Q button to confirm input.

Display on VAS5051:

1

-

Channel 3 read and test

2

-

Consumption-display

3

-

Keypad - only direct input via the keypad is possible

4

-

The sliding bar is positioned on the current adaptation value 100

NOTE:

-

Value entered must be between 85% and 115%.

-

Value must be entered in steps of 5%.

-

If the value "100" was changed due to a customer complaint, the changed value must be transferred when replacing instrument cluster.

Change adaptation value via direct input = "B - Change adaptation value via direct input". 
Enter 5-digit adaptation value. Fill empty spaces with "0".

Example:
Desired input value: 90%

Keypad input: 00090

NOTE:  The "Save" button does not appear if an incorrect value was entered! 

Display on VAS5051 after performed adaptation:

1

-

Channel 3 Value 90 stored