Specification: 10
(request for "Automatic air recirculation" available, requirement is fulfilled, A/C switches to air recirculating mode)

-

Wait a short period time (approx. 1 minute, depending on amount of test gas sprayed in sensor).

-

Read value indicated in display field -1-.
-

Specification: 00 or 0 
(no request for "air recirculation mode", climate control in fresh air mode)

or
-

Specification: 60 (Partial air recirculation mode)

NOTE:  In order to avoid quick shifting from the recirculating air/fresh air flap, the requirement from the sensor for "Automatic air recirculation" mode
is at least 25 seconds (minimum duration period), especially if the pollutant concentration has been reduced considerably so that recirculating air mode is
no longer necessary.

-

Operate switch for wiper/washer system until windshield washer pump -V5- has been cycled for approx. 2 seconds.

-

Read value indicated in display field -1-.
-

Specification: 30
(Requirement for recirculating air due to washer/wiper system, A/C switches for approx. 15 seconds to the air recirculating mode)

-

Wait a short period time.

-

Read value indicated in display field -1-.
-

Specification: 00 or 0
(no request for "air recirculation mode", climate control in fresh air mode)

or
-

Specification: 60 (Partial air recirculation mode)

NOTE:

-

Depending on the composition of the windshield washer fluid, the sensor can determine impurities in the air and request for "Automatic air
recirculation".

-

If when activating the wiper/washer system the mode does not switch over to recirculating air, check the wiring connection between A/C Control
Head -E87- and Wiped Washer Intermittent Relay -J31- (the information "windshield washing" is send via a separate wiring connection to A/C
Control Head -E87-) (Read measuring value block display group 017). Refer to Scan Tool Testing/Measuring Value Blocks (Function 08)/Display
Group 017" under "Heating and Air Conditioning", See: Heating and Air Conditioning/Testing and Inspection 

If the functions of the Sensor for air quality - G238- is OK for this test and there is a customer complaint continue as follows:

-

Check dust and pollen filter for dirt.

-

Connect VAS 5051 and select "Read measuring value block" function 08.

-

A second technician is required because the indicated values must be read out in the vehicle interior.

-

Observe safety caution notes.

-

Enter display group number "015".

-

Drive vehicle to area with relatively clean ambient air (system operates in fresh air mode).

-

Now drive vehicle into an area with heavily polluted ambient air (e.g. on a street construction or truck traffic).

-

Check indications shown in display fields -1- and -2- Display fields -1- and -2- must change when driving through a diesel exhaust cloud.
Meaning: See Read measuring value block display group 015 (See overview of display groups).  Refer to Scan Tool Testing/Measuring Value
Blocks (Function 08)" under "Heating and Air Conditioning", See: Heating and Air Conditioning/Testing and Inspection 