Connect up voltage tester VAG 1527 B as follows.

-

Briefly operate starter.
^

LED must light

-

Switch ignition off.

If LED does not light:
-

Use wiring diagram to check for open circuit in wiring from contact 1 of connector via fuse to fuel pump relay.

-

Use wiring diagram to eliminate open circuit in wiring.

If LED lights:

Checking actuation
^

Vehicle diagnostic, testing and information system VAS 5051 connected up; vehicle self-diagnosis and vehicle system "01 Engine electronics"
selected. Ignition must be on.

-

Connect voltage tester V.A.G. 1527 B to contacts 1 (positive) and 2 of connector.

Indicated on VAS 5051:
-

From list -1- select diagnostic function "03- Final control diagnosis".

-

Touch > key, until Valve -1- for camshaft adjustment -N205- is activated.
^

LED must flash

-

Touch > key again, until Valve -2- for camshaft adjustment -N208- is activated.
^

LED must flash

-

Terminate function "03- Final control diagnosis" by touching < key.

-

Switch ignition off.

If LED does not flash or if it is permanently lit: