Allroad Quattro V8-4.2L (BAS) (2004)
Air Door Actuator / Motor: Service and Repair
Recirculation Flap Motor -V113-
Recirculation Flap Motor -V113-, Removing And Installing
NOTE: This positioning motor actuates the fresh air/recirculating air flap.
-
Remove glove box
-
Recirculation Flap Motor -V113-, removing.
-
Disconnect harness connector -A-.
-
Remove bolt -B-.
NOTE: When removing screw -B-, if necessary reach the bolt from underneath in the recirculating intake area.
-
Remove bolts -C-.
-
Remove positioning motor.
Notes for installation:
-
After installing, always carry out On Board Diagnostic (OBD) of air conditioning system.
-
Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm on the positioning motor).
-
When installing positioning motor; make sure guiding pin -D- engages properly in lever -E-.