audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Not Available For Manufacturer's Scan Tool|Page 5722 > < Not Available For Manufacturer's Scan Tool|Page 5720
Page 5
background image

-

Check the following circuit connections for open circuits and shorts to ground and/or battery positive (+):

Connector terminal

Test box V.A.G 1598/22 Socket

2

16

-

Repair short circuit and/or circuit malfunction using circuit diagram

If no problem is found, but the diagnosis pump still does not work during the Output check diagnosis:

-

Replace Leak Detection Pump (LDP).

-

Observe the measures after reconnecting the ECM

Input circuit checking - Vehicles with mechanical accelerator operation

-

Input circuit checking - Vehicles with mechanical accelerator operation.

WARNING:  To avoid damaging electrical components, select the appropriate measurement settings on the measuring device before connecting to the
components.

-

Check the following circuit connections for open circuits and shorts to ground and/or battery positive (+):

Connector terminal

Test box V.A.G 1598/22 Socket

1

37

-

Repair short circuit and/or circuit malfunction using circuit diagram

-

Observe the measures after reconnecting ECM

Not Available For Manufacturer's Scan Tool|Page 5722 > < Not Available For Manufacturer's Scan Tool|Page 5720