Page 7
background image

-

Repair circuit malfunction using circuit diagram

If no problem is found, but the diagnosis pump still does not work during the Output check diagnosis:

-

Replace Leak detection pump (LDP) -V144-.

-

Observe the measures after reconnecting ECM.

Input circuit checking - Vehicles with electronic engine power control (drive-by wire)

-

Connect test box VAG1598/31 to the circuit harness connector; do not connect the ECM. Connect the ground clip of the test box to ground (not
shown in illustration).

WARNING:  To avoid damaging electrical components, select the appropriate measurement settings on the measuring device before connecting to the
components.

-

Check the following circuit connections for open circuits and shorts to ground and/or battery positive:

Connector terminal

Test box VAG 1598/31 Socket

1

80

-

Repair circuit malfunction using circuit diagram

-

Observe the measures after reconnecting ECM