audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking Secondary Air Injection (AIR) Pump Relay Power Supply|Page 5761 > < Checking Secondary Air Injection (AIR) Pump Relay Power Supply|Page 5759
Page 5
background image

-

Disconnect connector -1- at secondary air injection (AIR) pump motor V1 01 _.

-

Connect voltage tester V.A.G. 1527 B between contacts -1- and -2-.
^

Vehicle diagnostic, testing and information system VAS 5051 connected; vehicle self-diagnosis and vehicle system "01- Engine electronics"
selected. Ignition must be on.

Indicated on VAS 5051:

-

From list -1- select diagnostic function "03- Final control diagnosis".

-

Keep touching > key, until the secondary air injection (AIR) solenoid valve -J299- is activated.
^

LED must flash

-

Terminate function "03- Final control diagnosis" by touching < key.

If LED does not flash:
-

Perform the following checks marked with a dot.
^

Use wiring diagram to check for open circuit in wiring from contact 2 of connector to secondary air injection (AIR) pump relay J299- (in relay
carrier in plenum chamber electronics box, position 2).

^

Use wiring diagram to check for open circuit in wiring from contact 1 of connector to ground.

-

Use wiring diagram to eliminate open circuit in wiring.

If no fault is found:
-

Replace secondary air pump.

Checking Secondary Air Injection (AIR) Pump Relay Power Supply|Page 5761 > < Checking Secondary Air Injection (AIR) Pump Relay Power Supply|Page 5759