background image

Shift Interlock Solenoid: Testing and Inspection

CVT A/T 01J

Shift Lock Solenoid -N110-, checking

Note:  This test must be performed if the specified values in the voltage measurement are not reached.

Additional special tools and equipment

^

Connector test U V.A.G 1594 A

Test sequence

^

Remove cover for shift control mechanism.

^

Disconnect harness connector at Shift lock solenoid -N110 -A-. 

^

Attach multimeter for resistance measurement between contacts -B-.
^

Specified value: 22.3 ± 1 Ohms

If the specified value is not reached:
^

Replace shift lock solenoid.