Check fuse S234 (in fuse box, position 34).

^

Use wiring diagram to check for open circuit in wiring from secondary air injection (AIR) pump relay -J299- (in 3-position relay carrier in
plenum chamber electronics box) via fuse S234 (in fuse box, position 34) to fuel pump relay.

-

Use wiring diagram to eliminate open circuit in wiring.

Checking actuation of secondary air injection (AIR) pump relay
-

Switch ignition off.

-

Disconnect secondary air injection (AIR) pump relay.

-

Connect voltage tester V.A.G 1527 B as follows.

Indicated on VAS 5051:
-

From list -1- select diagnostic function "03- Final control diagnosis". 

-

Keep touching > key, until the secondary air injection (AIR) solenoid valve -J299- is activated.
^

LED must flash 

-

Terminate function "03- Final control diagnosis" by touching < key. 

-

Switch ignition off.

If LED does not flash: