Battery: Testing and Inspection
Electrolyte Level, Checking

Electrolyte Level, Checking

WARNING!
Observe safety precautions when handling battery acid.

Appropriate safety clothing is required.

Illuminate the inner part of the battery housing using only a flashlight.

Never illuminate the interior of the battery housing using an open flame.

Never use an open flame or a burning cigarette near batteries.

When disposing of batteries, disposal regulations for batteries and for sulfuric acid must always be observed.

To ensure proper sealing of the different battery plug systems, it is necessary that the original battery plugs are threaded into the battery
openings. In case of loss or damage, only original sealing plugs of the same type may be used.

The plugs must be equipped with an O-ring seal.

Special Tools and Equipment

-

VAS 4045 battery filler bottle

-

Commercially available hydrometer

NOTE:

-

Maintaining the correct electrolyte level in the battery is an important factor affecting the length of the battery's service life.

-

Batteries which have visible minimum and maximum marks require only visual inspection of the outside of the battery to check the electrolyte
level.

-

The electrolyte level must be above the minimum mark, but may extend only as far as the maximum mark.

-

For batteries on which the minimum and maximum marks are hard to see, or if the electrolyte level is not visible due to the opacity of the battery
casing, the plugs must be removed. Then it is possible to check the electrolyte level by visually inspecting the inside of the battery.

-

The electrolyte level must stop at the inside electrolyte level mark (plastic peg).  This corresponds to the exterior max. mark.