Remove hex nut -3- (size = 10 mm) at battery retaining bracket -2-.

-

Disconnect elbow of central venting system (arrow).

-

Lift battery out of plenum chamber.

Installing

Installation is the reverse of removal.  

Tightening torques

Component

Nm

Battery terminal to battery post

Bolt at retaining bracket

15

Batteries with central gas venting

WARNING!
New style batteries with central venting system must be installed.
Original battery covers must always be used. The plugs must be equipped with an O-ring seal.

There are two types of batteries with a central venting system:

-

Batteries with a hose or nozzle attached to the central venting system

-

Batteries without a hose or nozzle attached to the central venting system

NOTE:

-

The latest generation of batteries has a central venting system and a flashback protector in the form of a so-called "frit". Function: Gas produced
when charging leaves the battery through a central opening on the top part of the side covering. A flashback protector is also integrated at the same