Hydraulic Control Assembly - Antilock Brakes: Pressure, Vacuum and Temperature Specifications

PRESSURE DROP SPECIFICATIONS

High Pressure ............................................................................................................................................................................................  50 bar (725 lbs)

Hold For .....................................................................................................................................................................................................  45 seconds
Allowable Pressure Drop .......................................................................................................................................................  Less Than 4 bar (58 psi)

Low Pressure ................................................................................................................................................................................................  6 bar (87 psi)

Hold For ........................................................................................................................................................................................................  3 minutes
Allowable Drop ..................................................................................................................................................................  Less Than 1 bar (14.5 psi)

NOTE:  Checked at either front brake caliper