Check wiring for short circuit to GND between intake manifold change-over valve connector terminal 2 and test box socket 3.

If LED does not blink:
-

Check wiring for continuity between intake manifold change-over valve connector terminal 2 and test box socket 3.
^

Specified reading: maximum 1.0 ohm 

-

If necessary, eliminate short circuit to GND or wiring break between intake manifold change-over valve connector terminal 2 and terminal 3 of
ECM connector C.

If there is no wiring break or short circuit:
-

Replace ECM.