Cabriolet V6-2.8L (AFC) (1995)
Shift Interlock Solenoid: Testing and Inspection
Checking Clearence
CHECKING CLEARANCE BETWEEN SELECTOR LEVER AND SHIFT LOCK SOLENOID
-
Selector lever in "R" position
-
The gap between the selector lever and the shift lock solenoid must be 0.6-1.4 mm with lever in "R" position.
Measure as shown using feeler gauge -A-.
Specification: 0.6-1.4 mm (0.024-0.055 inch)
-
The clearance can be adjusted by moving the solenoid in the mounting holes.