Q7 Quattro V6-3.6L (BHK) (2007)
-
Pull manual release lever - arrow - upward.
‹› When manual release lever is raised, Shift Lock Solenoid (N110) operating lever - 1 - swings into installation position.
-
At the same time, position Shift Lock Solenoid (N110) at an angle in guide from above.
-
Press Shift Lock Solenoid (N110) into guide until it engages.
‹› Shift Lock Solenoid (N110) ball head - 2 - must engage in operating lever on selector mechanism.