audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Basic A/C System|Page 8233 > < Basic A/C System
Page 2
background image

-

Pull out retaining plate - B - with control motors downward.

-

Mark connectors - D - and - E - (risk of interchange) and disconnect them.

-

Disengage mount for wiring harness - F - from retaining plate - B -.

Installing

-

Check levers of both control motors - A - and -  B -, retaining plate can only be installed correctly when they are located in the position depicted
(service position).

‹› Position - E - shows the respective adjustment range of the control motors.

‹› If both control motor levers are not located in the position depicted, the control motor(s) may be connected via a 5A fuse to a 12 V battery e.g.

using an adapter lead => [ Connecting Adapter Cable to Activate Control Motors ] See: Service and Repair/Procedures/Connecting Adapter Cable
to Activate Control Motors (or an adapter lead from connector test kit (V.A.G 1594/C) to terminals " 5" and "6"). Rotate control motor for only as
long until it has reached the position depicted (the turning direction can be reversed by swapping Plus and Minus).

-

Check position of threaded plates - G -.

‹› Bolts - F - are used as a guide when installing retaining plate, if they are screwed in too far, the retaining plate cannot be installed, if they are not

screwed in far enough, it may possibly cause noise.

-

Connect connectors to control motors (note the assignment, risk of interchange).

-

Insert retaining plate on to bolts - F -, when doing this make sure that studs on levers of control motors - A - and -  B - are guided into lever guides
on flaps - C - and -  D -.

-

Slide retaining plate - B - with control motors on to heating & A/C unit from below.

Basic A/C System|Page 8233 > < Basic A/C System