audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Heater and Oxygen Sensor 2 Heater, Checking|Page 1145 > < Oxygen Sensor Heater and Oxygen Sensor 2 Heater, Checking|Page 1143
Page 3
background image

Specified value: 0.400 to 0.500 Volts

-

Switch the ignition off.

If the specified value was obtained:

-

Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) or Oxygen Sensor (O2S) 2 Behind Three Way Catalytic
Converter (TWC) (G131).

If the specified value was not obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Replacing ] See: Powertrain
Management/Computers and Control Systems/Engine Control Module/Service and Repair/Engine Control Module, Replacing.

-

Using a Multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminals
to the Motronic Engine Control Module (ECM) (J623) or Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131)
electrical harness connector T94 terminals for an open circuit.

Specified value: 1.5 ohms Max.

If the specification was not obtained:

-

Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the faulty wiring connection.