Remote Battery Jumper Terminal: Customer Interest
Electrical - No Start/EPC Light ON/DTC P0088

27 - No start, EPC light on, Battery will not charge (DTC P0088)

97 11 22 

2025746/1 

March 8, 2011.

AFFECTED VEHICLES

CONDITION
Customer complaint includes one of the following:

^ No Start

^ EPC light on

^ Battery will not charge

^ DTC P0088 - Rail Fuel Pressure too high sporadic

In many cases the customer complaints cannot be duplicated.

TECHNICAL BACKGROUND

Loose battery connections can cause intermittent vehicle issues.

PRODUCTION SOLUTION

Not Applicable.

SERVICE

1. Inspect and Tighten B+ jump post connections if necessary.

2. Inspect and tighten Terminal 30 connection in plenum box if necessary. Be sure to inspect both top and bottom nut on the plenum box connection.

3. If damage has occurred to the jumper point due to high electrical resistance, replace jumper point.