Alignment: Service and Repair
ACC Setting Device VAS 6190, Converting for Adjustment Procedure

ACC Setting Device VAS 6190, Converting for Adjustment Procedure

Special tools, testers and auxiliary items required

‹› ACC Adjustment Device (VAS 6190)

Before performing adjustment, check in which mount the vertical slits on the (VAS 6190) are located. (VAS 6190) may have to be adapted
before performing adjustment.

The (VAS 6190) must be adapted before adjustment procedure. If this is done during the adjustment procedure, the pre-calibration on the
(VAS 6190) must be repeated.

-

For the adjustment procedure, the vertical slits in mounts -  1 - through - 4 - must be inserted so that laser beam is approximately centered
vertically when it contacts the sensor lens.

-

The original nut at the top of the horizontal slits must be replaced with a standard nut - 3 -.