background image

1

Windshield

2

Adhesive sealing material

‹› Apply adhesive at distances to window edge listed below.

‹› Dimension - a - = 2 mm

‹› Dimension - b - = 18 mm

‹› Dimension - c - = 8 mm.

‹› Dimension - d - = 18 mm

3

Plenum chamber cover

‹› Retaining strip can only be pressed in after minimum window adhesive curing time.

-

After preparatory work has been performed, apply the adhesive.

-

Position complete surface of nozzle - 2 - onto window. 