R8 Quattro Coupe V10-5.2L (BUJ) (2010)
-
Note the value read off.
-
Repeat measuring procedure in the same manner for the other rear wheel on the other side of the (VAS 6350/4).
The distance value must be the same on both sides.
If values are not identical:
-
Adjust the (VAS 6350/4) until values on both sides are identical.
When aligning the (VAS 6350/4) make sure the (VAS 6350/3) from the (VAS 6350/4) till strikes the center of the Audi rings and the indicator of the
level remains centered. If necessary, make further corrections.
-
Measure the height of the (VAS 6350/4), dimension - H - (top edge platform - floor).
The measured distance and height must now be entered in the (VAS 5051B) in millimeters.
Performing Calibration
In (VAS 5051B), select operating mode "Guided Fault Finding".
-
Select the corresponding vehicle data in the "vehicle selection " menu.
-
Select "rear view camera system".
-
Select "functions".
-
Select "Calibration".