audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

General Information|Page 7392 > < General Information|Page 7390
Page 6
background image

-

Note the value read off.

-

Repeat measuring procedure in the same manner for the other rear wheel on the other side of the (VAS 6350/4).

The distance value must be the same on both sides.

If values are not identical:

-

Adjust the (VAS 6350/4) until values on both sides are identical.

When aligning the (VAS 6350/4) make sure the (VAS 6350/3) from the (VAS 6350/4) till strikes the center of the Audi rings and the indicator of the
level remains centered. If necessary, make further corrections.

-

Measure the height of the (VAS 6350/4), dimension -  H - (top edge platform - floor).

The measured distance and height must now be entered in the (VAS 5051B) in millimeters.

Performing Calibration

In (VAS 5051B), select operating mode "Guided Fault Finding".

-

Select the corresponding vehicle data in the "vehicle selection " menu.

-

Select "rear view camera system".

-

Select "functions".

-

Select "Calibration".