audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Central Tube|Page 8278 > < Central Tube|Page 8276
Page 3
background image

Installation

-

Check adjusting element adjusting nuts - 1 - for ease of movement - arrow -.

-

Install adjustment nuts all the way, but do not tighten.

-

Insert central tube in body according to markings applied.

-

Align central tube according to markings applied to A-pillar during removal.

-

Tighten left and right central tube nuts.

Further installation is performed in reverse sequence of removal, but observe the following:

Check location of instrument panel central tube

-

Insert instrument panel to test.

-

Secure the instrument panel at the left and right to the instrument panel bracket.

-

Close doors.

-

Check whether gap dimension between instrument panel and left and right doors is even.

-

Check whether height of instrument panel aligns with molding in door trim.

If the adjustment is not correct:

Central Tube|Page 8278 > < Central Tube|Page 8276