Remove bolts - arrows -.
-
Remove the bolt - 1 - and then remove the coolant pump housing - 3 -.
-
To remove the coolant pump, install two M6 x 15 bolts - arrows - into the threaded holes in the coolant pump - 1 -.
-
Turn each bolt 1/2 turn further until it is possible to remove the coolant pump.
Installing
‹› Tightening specifications, refer to => [ Coolant Pump Assembly Overview ] See: Coolant Pump Assembly Overview.
Installation is in reverse order of removal, note the following:
‹› Replace the seal, the O-rings and the coolant connection pipe.
‹› Secure all hose connections with hose clamps appropriate for the model.
-
Slide the coolant pump onto the shaft. At the same time the alignment bushing - arrow - must fit into the opening in the coolant pump.