Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

Ambient Air Temperature Sensor, Checking

Special tools, testers and auxiliary items required

‹› multimeter.

‹› Wiring diagram.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Preliminary Check

Start diagnosis

-

Connect the scan tool.

-

Engine MUST be at room temperature.

-

Switch the ignition on.

-

Using the scan tool, check the ambient air temperature:

If the specified value was obtained:

-

Fault may be intermittent. Check for proper connection, damaged wiring or loose terminals.

‹› The reading will default to 419° F if the circuit is open or shorted to ground.

If the specified value was Not obtained:

Checking internal resistance

-

Turn the key off.

-

Disconnect the Ambient Air Temperature Sensor (G17) electrical harness connector.

-

Using a multimeter, check the Ambient Air Temperature Sensor (G17) terminals 1 to 2 for resistance.

Use the chart below for the specified values:

Specified values: